Влияния фильтров различной степени очистки на аэроионный состав воздуха

dc.contributor.authorМарченко, В. Г.
dc.contributor.authorЛагутин, А. Е.
dc.contributor.authorЛипа, А. И.
dc.contributor.authorПономаренко, А. П.
dc.contributor.authorMarchenko, Valery G.
dc.contributor.authorLagytin, Anatoliy E.
dc.contributor.authorLipa, Alexander I.
dc.contributor.authorPonomarenko, Anatoliy P.
dc.date.accessioned2021-05-14T12:14:37Z
dc.date.available2021-05-14T12:14:37Z
dc.date.issued2015
dc.descriptionВлияния фильтров различной степени очистки на аэроионный состав воздуха = Different types filters vary ions concentration of indoor air / В. Г. Марченко, А. Е. Лагутин, А. И. Липа, А. П. Пономаренко // Зб. наук. пр. НУК. – Миколаїв : НУК, 2015. – № 6 (462). – С. 96–100.uk_UA
dc.description.abstractПроведено аналiз впливу фiльтрiв рiзного ступеня очищення на концентрацiю аероiонiв. Дана рекомендацiя щодо мiсця установки у СКП пристроїв штучної iонiзацiї припливного повiтря. Встановлено, що фiльтри будь-якого ступеня очищення вловлюють понад 90% iонiв як негативного, так i позитивного заряду. Можливе збiльшення концентрацiї iонiв пiсля фiльтра (якщо таке спостерiгається) пояснюється високим ступенем еманацiї радiоактивних речовин з огороджувальних конструкцiй будiвель.uk_UA
dc.description.abstract1Incoming air has to be cleaned in the air conditioning system by the filters of different types. This mechanical processing varies air ions concentration, primarily negative ions. However, nowadays in the research works [1, 2, 3] there is not any consensus on that problem. Therefore, we have reviewed this question more deeply in the article. The filters of three efficiency groups (filtering ability) were selected according to European standard EN779/2012. Tested filters were placed in the outlet section of the plastic duct with the attached fan. Just behind the filters there was the small air ions counter МAC-01 (Russia). We located the bipolar effluence ions generator IWS-12D1-AE (Israel) with the productivity of 5·109 ion/sec and electrode voltage of U = 6 kV on 250 mm from the outlet section of the duct. Due to the ions flow distributed uniformly over the filter surface. The lab background ions concentration was n+ = 120 ion/cm3, n- :: 100 ion/cm3. The data show radioactive contaminants in building materials do not influence on the background ions concentration. Consequently, we can ignore it. In the beginning of the experiment, the fan and the ionizer were functioning, but filters were not placed in the duct. Owing to the step, we have determined ions concentration in front of the filters: n- = 58.6·103 ion/cm3 and n+ = 14.2·103 ion/cm3. Then the filters were changed in turn during the experiments and we have carried out the measurements behind them. Having analyzed the experimental data, we are able to conclude: – Air ionizers must be the last unit for the air processing and they have to be placed after filters. Researching results show that any type filters catch above 90% of negative and positive ions. – The only explanation of ions concentrations increase after the filter (if we observe such thing) is due to high emanation of radioactive contaminants in building materials. This process is observed in the tight spaces, especially without the ventilation systems [1, 2, 4].uk_UA
dc.description.abstract2Проведен анализ влияния фильтров различной степени очистки на концентрацию аэроионов. Дана рекомендация в отношении места установки в СКВ устройств искусственной ионизации приточного воздуха. Установлено, что фильтры любой степени очистки улавливают свыше 90 % ионов как отрицательного, так и положительного заряда. Возможное увеличение концентрации ионов после фильтра (если такое наблюдается) объясняется высокой степенью эманации радиоактивных веществ из ограждающих конструкций зданий.uk_UA
dc.identifier.issn2311-3405 (Print)
dc.identifier.issn2313-0415 (Online)ru
dc.identifier.urihttps://eir.nuos.edu.ua/handle/123456789/4115
dc.language.isoruuk_UA
dc.relation.ispartofseries628.85:544.431.143uk_UA
dc.subjectионизацияuk_UA
dc.subjectфильтрыuk_UA
dc.subjectiонiзацiяuk_UA
dc.subjectфiльтриuk_UA
dc.subjectionizationuk_UA
dc.subjectfiltersuk_UA
dc.titleВлияния фильтров различной степени очистки на аэроионный состав воздухаuk_UA
dc.title1Different types filters vary ions concentration of indoor airuk_UA
dc.title22015
dc.typeArticleuk_UA

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
Marchenko.pdf
Розмір:
474 KB
Формат:
Adobe Portable Document Format
Опис:
статья
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
7.05 KB
Формат:
Item-specific license agreed upon to submission
Опис:

Зібрання